High-Quality Lrd 16A Thermal Overload Relay for Industrial Use

Product Details
Customization: Available
Theory: Thermal Relay
Usage: Household Appliances Relay
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001
  • High-Quality Lrd 16A Thermal Overload Relay for Industrial Use
  • High-Quality Lrd 16A Thermal Overload Relay for Industrial Use
  • High-Quality Lrd 16A Thermal Overload Relay for Industrial Use
  • High-Quality Lrd 16A Thermal Overload Relay for Industrial Use
  • High-Quality Lrd 16A Thermal Overload Relay for Industrial Use
  • High-Quality Lrd 16A Thermal Overload Relay for Industrial Use
Find Similar Products
  • Overview
  • Company Profile
  • Manufacturing Technique
  • Exhibition Display
  • Certifications
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
LRD10
Phase
3
Electricity Type
Ac
Number of Pole
3
Load
Medium Power Relay
Protective Characteristics
Sealed Relay
Action Principle
Electromagnetic Type
Size
Miniature
Type
Electric Parameter Relay
Application
Electronic Thermal Overload Relays for Cjx2-D Cont
Rated Operation Voltage (Ue)
690V
Ambient Temperature
-20~ +60°c
Surge Withstand
6kv
Degree of Protection
IP20
Standards
IEC/En 60947-4-1, IEC/En 60947-5-1
Warranty
2year
Transport Package
50PCS/Carton
Trademark
CANGO or OEM
Origin
China
HS Code
8536490000
Production Capacity
100000PCS/Year

Product Description




 
PRODUCT NAME: THERMAL OVERLOAD RELAY
MODEL NUMBER:LRD
Electronic thermal overload relays for CJX2-D contactor

1.Description
3-pole thermal overload relays are designed to protect a.c. circuits and motors against: overloads, phase failure, long starting times and prolonged stalling of the motor.
1 Adjustment dial Ir.
2 Test button.
Operation of the Test button allows:
- checking of control circuit wiring,
- simulation of relay tripping (actuates both the N/Oand N/C contacts).
3 Stop button. Actuates the N/C contact; does not affect the N/O contact.
4 Reset button.
5 Trip indicator.
6 Setting locked by sealing the cover.
7 Selector for manual or automatic reset.
High-Quality Lrd 16A Thermal Overload Relay for Industrial Use
Rated or scale of rated current(A) M(A) gG(A) Model of contactor Model
0.1-0.16 0.25 2 D09-D38 LRD-01
0.16-0.25 0.5 2 D09-D38 LRD-02
0.25-0.4 7 2 D09-D38 LRD-03
0.4-0.63 1 2 D09-D38 LRD-04
0.63-1 2 4 D09-D38 LRD-05
1-1.6 2 4 D09-D38 LRD-06
1.6-2.5 4 6 D09-D38 LRD-07
2.5-4 6 10 D09-D38 LRD-08
4-6 8 16 D09-D38 LRD-10
5.5-8 12 20 D09-D38 LRD-12
7-10 12 20 D09-D38 LRD-14
9-13 16 25 D12-D38 LRD-16
12-18 20 35 D18-D38 LRD-21
16-24 25 50 D25-D38 LRD-22
23-32 40 63 D25-D38 LRD-32
32-38 50 80 D32-D38 LRD-35
17-25 25 50 D40-D95 LRD-3322
23-32 40 63 D40-D95 LRD-3353
30-40 40 100 D40-D95 LRD-3355
37-50 63 100 D40-D95 LRD-3357
48-65 63 100 D40-D95 LRD-3359
55-70 80 125 D40-D95 LRD-3361
63-80 80 125 D40-D95 LRD-3363
80-104 100 160 D40-D95 LRD-3365
Environment
Conforming to standards IEC/EN 60947-4-1, IEC/EN 60947-5-1
Degree of protection Conforming to IEC 60529   Protection against direct finger contact IP20
(front face)
Climatic withstand Conforming to IACS E10
Ambient air temperature around the device Storage ºC -60...+70
Normal operation, without ºC -20...+60
derating (IEC 60947-4-1)
Minimum /maximum operating ºC -20...+70
temperatures (with derating)
Operating positions without derating In relation to normal   Any position.
vertical mounting plane When mounting on a vertical rail, use a stop.
Flame resistance Conforming to60695-2-11 ºC 850
Shock resistance Permissible acceleration   15 gn-11ms
conforming to IEC 60068-2-7
Vibration resistance (2) Permissible acceleration   6 gn
conforming to IEC 60068-2-6
Dielectric strength at 50Hz Conforming to IEC 60255-5 kV 6
Surge withstand Conforming to IEC 60801-5 kV 6
Electrical characteristics of power circuit
Relay type LRD01   LRD21 LRD313   LRD3322   LRD4365
...16, ...35, ...365 ...33696 ...4369
Tripping class Conforming to UL508, IEC 60947-4-1   10A   10A 10A   10A   10A
Rated insulation voltage (Ui) Conforming to IEC 60947-4-1 V 690
Conforming to UL,CSA V 600
Rated impulse withstand voltage (Uimp) kV 6
Rated operational voltage (Ue) V 690
Frequency limits Of the operating current Hz 0..400
Setting range Depending on model A 0.1...13   12...38 9...80   17...140   80...140
Auxiliary contact characteristics
Conventional thermal current A 5
Max. sealed consumption of the operating coils of controlled contactors (Occasional operating cycles of contact 95-96) a.c. supply, AC-15 V 120 240 380 480 500 600
A 3 1.5 0.95 0.75 0.72 0.12
d.c. supply, DC-13 V 125 250 440
A 0.22 0.1 0.06
Protection against short-circuits By gG, BS fuses. A 5
Maximum rating or by GB2
High-Quality Lrd 16A Thermal Overload Relay for Industrial UseHigh-Quality Lrd 16A Thermal Overload Relay for Industrial UseHigh-Quality Lrd 16A Thermal Overload Relay for Industrial UseHigh-Quality Lrd 16A Thermal Overload Relay for Industrial Use
 

High-Quality Lrd 16A Thermal Overload Relay for Industrial Use

 
Company Profile

Zhejiang Kangge Electric Co.,Ltd, with the logo CANGO, established in 2010, located in Yueqing Industrial Park, Zhejiang Province,is one of the technological enterprises in Zhejiang province,who devotes itselfto the design,R&D,manufacture, sale and service of electrical products and solar system.Since the establishment in 2010,Kangge insists on the principle of"honest-based,wining success through quality", and develop its spirit of"unity, communication, development and innovation".We continuously develop and innovate in the area of electrical products and solar system , perfect series products, to meet the demand of domestic and abroad customers.
Kangge's existing plant area is more than 50000 square meters.Total employees are more than 200,among which,15 are senior management employees;20 are professional technical engineers;8 are R&D employees.Up to now,all of Kangge's products have passed CE,the test of China Compulsory Product Certification(CCC test),ISO9001 Quality and Management System Certification,ISO14000 Environmental Management System Certification,as well as OHSAS18000 Occupational Health and Safety System Certification.

High-Quality Lrd 16A Thermal Overload Relay for Industrial Use

Manufacturing Technique

High-Quality Lrd 16A Thermal Overload Relay for Industrial Use

 
Exhibition Display

High-Quality Lrd 16A Thermal Overload Relay for Industrial Use

Certifications

High-Quality Lrd 16A Thermal Overload Relay for Industrial Use

Packaging & Shipping

High-Quality Lrd 16A Thermal Overload Relay for Industrial Use

FAQ

Q:Your Thermal Overload Relay seems perfect but what's the difference between you and other suppliers? Because I find some cheaper price from others!
A: We strick in high quality. Products with low temperature rise,long life time and good corrosion resistance.Products pass the test of CQC and CE.

Q: Is your company a manufacturer for a trading company?
A: We are professional manufacturer in industrial electrical appliances since 2010 years.

Q:Can I get a sample for test before place order?
A:Of course.

Q:Can you print our own logo?
A:Yes, we provide OEM&ODM service.And we made a lot of customized products.

Q:How's the delivery?Because I really need them is urgently?
A:We will deliver sample in 2-5days.Mass production around 30 days.If you have urgent requirement, pls send us list to check with stock. We have sufficient stock for best-sellers.

Q: What's the payment method you accept ? 
A: We accept T/T, Paypal, Western union, L/C,Trade Assurance.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier